Compression Load Cells ( KRE2 )
 




      Parameters
 Rated Capacity (RC) 20,50,100,200,500 kgf 

1,2,3,5,10,20, tf(st)

 Rated Output 3 mv/v ±0.2%
 Non-Linearity 0.1% (RO) 
 Hysterisis 0.1% (RO) 
 Repeatability 0.1% (RO) 
 Zero Balance ± 1% (RO)
 Temp. Range
 Compensated
-10 o c to 70 o c
 Temp. Effect on Output 0.05% LOAD / 10o c
 Temp. Effect on Zero
 Balance
0.05% (RO) / 10o c
 Terminal Resistance
 Input
 Output

 385 W  ± 3.5%
 350 W  ± 5 W
 Electrical Connection  Cable f 10 x 300 cm, 4 core shielded
 Insulation Resistance (min)
 Bridge to Ground
 Shield to Ground
 2000 M Ohms
 1000 M Ohms
 Excitation Recommended 12 V
 Excitation (max) 20 V
 Safe Overload 150% (RC)

Dimension Table
 Rated
 Capacity
 in Kg
 A     f B  BSfDfDBfEFSfHIPQLCSRWeight  in Kg
 10-100 35 42 583985201581120133513010.510720.9
 200-500  45 528050142925121540154520014201201.9