Parameters

 Rated Capacity 300 gmf (AI) 400 gmf (AI)
 Rated Output  1 mv/v  1.5 mv/v
 Non-Linearity  0.02  0.01
 Hysterisis  0.02  0.015
 Repeatability  0.02  0.01
 Creep (% in RO/20 min)  0.03  0.02
 Zero Balance  2  2
 Temp. Range Compensated  -10 o c to 50 o c  -10 o c to 50 o c
 Temp. Range Safe  -10 o c to 70 o c  -10 o c to 70 o c
 Temp. Effect on Rated Output  0.02  0.03
 Temp. Effect on Zero Balance  0.04  0.1
  Terminal Resistance
Input
Output
 410 W  ± 5%
 350 W  ± 5%
 350 W  ± 5%
 350 W  ± 5%
 Electrical Connection  Cable f3.5 mm x 40 cm, 4 core shielded
 Insulation Resistance (min)
 Bridge to Ground
 Shield to Ground

 2000 M Ohms
 1000 M Ohms

 Excitation Recommended 10 V
 Excitation (max) 15 V
 Safe Overload 150% (RC)