Accessories
| Rated Capacity | Compression Uni Ball Assembly | Tension Rod and Bearing |
| 10 to 100 kgf | UBFBW-1 | REFBW-1 |
| 200 to 500 kgf | UEFBW-2 | REFBW-2 |
| |
 |
Click here to see product page
|
Parameters
| Rated Capacity (RC) | 10,20,50,100,200,500 kgf
(ss) |
| Rated Output |
2 mv/v ±0.2% |
| Non-Linearity | 0.03% (RO) |
| Hysterisis | 0.02% (RO) |
| Repeatability | 0.02% (RO) |
| Zero Balance | ±
1% (RO) |
Temp. Range Compensated | -10 o c to
70 o c |
| Temp. Effect on Output | 0.05% LOAD / 10o c |
Temp. Effect on Zero Balance | 0.05% (RO) / 10o c |
Terminal Resistance Input Output | 380 W
± 5% 350 W ± 5 W |
| Electrical Connection Cable | f
5 mm x 300 cm, 4 core shielded |
Insulation Resistance (min) Bridge to Ground Shield to Ground |
2000 M
Ohms
1000 M
Ohms |
| Excitation Recommended | 12 V |
| Excitation (max) | 20 V |
| Safe Overload | 150% (RC) |
|