Click here to see product page
|
Parameters
| FBC1 | FBC2 |
| Rated Capacity | 50,100,150, 200,250,350 kgf (AI) | 150,200,250, 350 kgf (st) |
| Rated Output |
2 mv/v ±5% |
| Non-Linearity | 0.02% (RO) |
| Hysterisis | 0.02% (RO) |
| Repeatability | 0.02% (RO) |
| Creep (% in RO/20 min) | 0.03% |
| Creep Recovery (% in RO/20 min) | 0.03% |
| Zero Balance |
±3% (RO) |
Temp. Range Compensated | -10 o c to
50 o c |
| Temp. Range Safe | -10 o c to
70 o c |
Temp. Effect on Rated Output | 0.012% LOAD / 10o c |
Temp. Effect on Zero Balance | 0.04% (RO) / 10o c |
Terminal Resistance Input Output | 410
W
± 5% 350 W ± 5% |
| Electrical Connection Cable | f
6.5 mm x 300 cm, 4 core shielded |
Insulation Resistance (min) Bridge to Ground Shield to Ground |
2000 M
W
1000 M
W |
| Excitation Recommended | 12 V |
| Excitation (max) | 15 V |
| Safe Overload | 150% (RC) |
|
|