translate in English Englishtranslate in Français Françaistranslate in Español Españoltranslate in Deutsch Deutschtranslate in Italiano Italianotranslate in Portugues Portugues

 
Single Point Load Cell ( FBC1/2 ) 
 

 

Click here to see product page

 

Parameters
 FBC1 FBC2
 Rated Capacity 50,100,150,
200,250,350 kgf (AI)
 150,200,250,
350 kgf (st)
 Rated Output  2 mv/v ±5% 
 Non-Linearity 0.02% (RO) 
 Hysterisis 0.02% (RO) 
 Repeatability 0.02% (RO) 
 Creep (% in RO/20 min) 0.03% 
 Creep Recovery  (% in RO/20 min) 0.03% 
 Zero Balance  ±3% (RO)
 Temp. Range
 Compensated
-10 o c to 50 o c
 Temp. Range Safe-10 o c to 70 o c
 Temp. Effect on Rated
 Output
0.012% LOAD / 10o c
 Temp. Effect on Zero
 Balance
0.04% (RO) / 10o c
 Terminal Resistance
 Input
 Output

 410 W  ± 5%
 350 W  ± 5%
 Electrical Connection  Cable f 6.5 mm x 300 cm, 4  core shielded
 Insulation Resistance (min)
 Bridge to Ground
 Shield to Ground

 2000 M W

 1000 M W

 Excitation Recommended 12 V
 Excitation (max) 15 V
 Safe Overload 150% (RC)

Privacy Policy and Terms and Conditions of use