Dimension Table
Rated Capacity |
600,800 Kgf | 1500
kgf | | L |
250 | 280 | | B | 70 |
80 |
| H | 82 | 106 |
| C | 13 | 13 |
| P | 18 | 22 |
| BS | 78 | 90 |
| F | 8 | 13 |
| TS | 76 | 84 |
| DH | 34 | 54 |
| D | 95 | 130 |
| J | M12,D.24 | M16,D.32 |
| K | 40 | 45 |
| P | 18 | 22 |
| M2 | f
28, D 23 | f
40, D.27 |
| M1 | f
18, D.59 | f
22, D.79 |
| Wt. Kg. | 3.5 | 5.6 |
| |
|
|
Click here to see product page
|
|
Parameters
|
Rated Capacity (RC) |
600, 800 & 1500 kgf (AI)
|
|
Rated Output (RD) |
2 m V/V
±0.5% |
| Non-Linearity | 0.025% (RO) |
| Hysterisis | 0.025% (RO) |
| Repeatability | 0.02% (RO) |
| Creep (% RO/20 min) | 0.025 % |
| |
| Zero Balance | ±
5% (RO) |
Temp. Range Compensated | -10o c to
+50o c |
| Temp. Range Safe | -20o c to
+70o c |
| Temp. Effect on Rated Output | 0.05% LOAD / 10o
c |
Temp. Effect on Zero Balance | 0.05% (RO) / 10o c |
Terminal Resistance Input Output | 410 W
± 5% 350 W ± 5 W |
| Electrical Connection Cable | f
6.5 mm x 300 cm, 4 core shielded |
Insulation Resistance (min) Bridge to Ground Shield to Ground |
2000 MW
1000 MW
|
| Excitation Recommended | 12 V |
| Excitation (max) | 20 V |
| Safe Overload | 150% (RC) |
|